High-purity compressed air is air treated to a stated limit for particles, water and oil at the point where it is used. It matters because air that touches products, instruments or process equipment carries any compressed air contamination the compressor and piping add. ISO 8573-1 gives manufacturers a common way to specify compressed air purity at each point of use. Treatment, such as compressed air filters and dryers, can then be matched to the real risk.
This article explains where compressed air contamination comes from and how to read an ISO 8573-1 purity class. It then shows how Parker Balston filters and dryers fit into a treatment plan that plant engineers can specify, install and verify.
Compressed air contamination is any particle, water, oil, gas or microorganism carried in the air stream beyond what the application allows. A compressor concentrates everything in the air it draws in, then adds contaminants of its own. The distribution system can add more on the way to the point of use. The main contaminants are:
Left untreated, these contaminants can corrode piping, foul valves and cylinders, upset sensitive instruments and spoil products. Water is often the root problem, because liquid water carries particles, washes lubricant downstream and supports microbial growth.
ISO 8573-1:2010 is the international standard, within the ISO 8573 series, that sets compressed air purity classes for particles, water and total oil. Parts 2 to 9 of the series describe how to test for each contaminant.
A specification is written as the standard, the edition and three class numbers in the order particles, water, oil. For example, ISO 8573-1:2010 Class 1:2:1 calls for Class 1 particles, Class 2 water and Class 1 oil.
The table below shows standard water and total-oil limits for the first four classes. It is a specification reference, not a claim that any Parker filter or dryer alone delivers these classes. According to Parker’s introduction to ISO 8573-1, lower class numbers mean cleaner air.
| ISO 8573-1:2010 class | Water: pressure dewpoint | Total oil (aerosol, liquid and vapour) |
|---|---|---|
| 1 | ≤ -70°C | ≤ 0.01 mg/m³ |
| 2 | ≤ -40°C | ≤ 0.1 mg/m³ |
| 3 | ≤ -20°C | ≤ 1 mg/m³ |
| 4 | ≤ +3°C | ≤ 5 mg/m³ |
Two points cause frequent confusion. First, the oil figure is total oil, so oil vapour counts as well as droplets.
Second, Class 0 does not mean zero contamination. Parker’s paper explains that Class 0 is a written limit, agreed between user and supplier, that is cleaner than Class 1 for a named contaminant. A “Class 0” claim with no stated limit has no meaning under the standard.
At the 10 November 2026 source check, ISO lists ISO 8573-1:2010 as published and a replacement work item as under development. Name the edition in a specification and recheck its status when ordering or validating a system.
Treating the whole plant to the strictest class wastes energy and money. Treating only in the compressor room leaves the distribution piping as an uncontrolled source of rust, condensate and biofilm. A practical approach is to set a class for each point of use:
Parker’s Balston compressed-air filtration guidance distinguishes Grade DX prefiltration, Grade BX fine coalescing and a separate adsorbent stage for trace oil vapour. Select the stages for the contaminants actually present; a coalescer’s aerosol-retention rating does not establish total-oil purity.
A coalescing filter is a filter that captures fine liquid aerosols and merges them into drops large enough to drain away. Balston coalescing filters use borosilicate glass microfibre elements. Fine liquid droplets collect on the fibres, merge into larger drops and drain to the bottom of the housing, where an automatic drain removes them. Because liquid drains as fast as it arrives, the element keeps its rated efficiency while wet.
Parker publishes the following Balston element ratings for 0.01 micron particles and droplets: Grade DX 93% and Grade BX 99.99%. Grade DX is used as a prefilter ahead of Grade BX in the documented two-stage arrangement. Treat these as grade-specific filter ratings, not a guarantee of delivered point-of-use purity.
For applications requiring a sterile-air stage, Parker’s Balston catalogue rates Grade SA cartridges at 99.9999+% for 0.01 micron particles. That is a Grade SA particle-efficiency rating, not a claim that every installation or product-contact process is sterile. Check the selected assembly’s operating, sterilization and validation instructions against the site’s requirements.
Pressure dewpoint is the temperature at which water vapour in compressed air condenses at its working pressure. Filters remove liquid water but not water vapour, so a dryer sets the pressure dewpoint.
Parker’s Balston membrane-dryer catalogue includes Model 76-series flow tables expressed for a -40 °C atmospheric dewpoint. The Model 75-A20 PSA description states an atmospheric dewpoint of -73 °C. Atmospheric dewpoint is not pressure dewpoint, so neither figure alone demonstrates an ISO water class. Specify the required pressure dewpoint at the actual operating conditions and verify the selected model’s performance. For an application overview, see our Parker membrane air dryer article.
A treatment train only delivers its rated purity when it is maintained. Maintenance teams can build these checks into their routines:
Clean compressed air also matters upstream of gas-generation equipment. Confirm the selected generator’s inlet-air requirements in its manual. For Canadian applications, review the Parker Balston filtration and nitrogen guide and ask Davis Controls to confirm the suitable model and availability.
For a complete overview of filtration, dryers and on-site gas generation, see our guide to Parker Balston filtration and nitrogen generation.
It specifies Class 1 for particles, Class 2 for water and Class 1 for total oil. In practice that means a pressure dewpoint of -40°C or lower and no more than 0.01 mg of total oil per cubic metre. The Class 1 particle limits also apply.
Not necessarily. Intake air can carry hydrocarbons, and ISO 8573-1 measures total oil, including vapour. Downstream filtration and testing are still needed to confirm the class you specified.
Final filters belong as close as practical to the point of use. That way, contaminants picked up in the distribution piping are removed before the air reaches the product or instrument.
Need help setting purity classes or sizing Parker Balston filters and dryers for your plant? Contact Davis Controls or call 1-800-701-7460 to talk to an application specialist.
Contact Davis Controls today about our state-of-the-art products and experience our expert application advice and reliable service!